SCV Climate

Heating and cooling equipment types explained

What each kind of system is, where it fits in a Santa Clarita Valley house, and how to read the ratings on a quote.

Short answer

Most valley homes have a split system: an outdoor unit, an indoor coil and a furnace or air handler in the attic. The main choices today are whether the outdoor unit is an air conditioner or a heat pump, and whether it is single-stage, two-stage or variable-speed. In dry heat, look at EER2 as well as SEER2, because EER2 describes performance on a hot afternoon.

The main system types

TypeWhat it isWhere it fits
Split AC with gas furnaceOutdoor condenser, indoor coil, gas furnace that also houses the blower.The most common existing setup in local tract homes.
Split heat pump with air handlerOutdoor unit that cools in summer and reverses to heat in winter. No combustion.Well suited to mild winters. A direct replacement path for AC plus furnace.
Dual fuelHeat pump paired with a gas furnace as backup heat.Rarely needed here. Winters are not cold enough to require backup.
Ductless mini splitSmall outdoor unit connected by refrigerant lines to one or more wall, ceiling or concealed indoor units.Additions, garages, converted rooms, homes without ducts, or a problem room the central system cannot reach.
Package unitEverything in one cabinet, on the roof or on a slab beside the house.Some older homes, manufactured homes and most small commercial buildings.
Whole-house fanA ceiling fan that pulls outdoor air through open windows and pushes house air out through the attic.Evening and night cooling in dry climates with a big temperature swing. Not for smoky or dusty days.
Evaporative coolerCools by evaporating water into the air stream.Works in dry heat, adds humidity, uses water, and brings in unfiltered outdoor air.

Single-stage, two-stage and variable-speed

This is the difference you will feel most.

  • Single-stage equipment is either fully on or off. It is the simplest and least expensive to buy.
  • Two-stage equipment has a low setting for mild conditions and a high one for peak heat.
  • Variable-speed (inverter) equipment adjusts output continuously. It runs long, quiet, low-power cycles and holds a steadier temperature.

A valley summer day moves through a wide range of cooling demand between 9 am and 9 pm. Equipment that can turn itself down handles the morning and evening hours more gracefully than equipment that can only cycle on and off. None of this helps if the system is the wrong size or the ducts leak, so settle sizing and duct condition first.

Reading the ratings

RatingMeasuresWhy it matters here
SEER2Cooling efficiency averaged over a season.The headline number. New split air conditioners sold in California must meet a regional minimum.
EER2Cooling efficiency at a single hot outdoor condition.Closer to what the unit does at 4 pm in July. Two units with the same SEER2 can differ here.
HSPF2Heat pump heating efficiency over a season.Compare between heat pumps.
AFUEShare of a furnace's fuel that becomes heat for the house.Compare between furnaces. Local furnaces must also be ultra-low-NOx models.
Sound ratingOutdoor unit noise in decibels.Matters on narrow side yards between houses.

SEER2, EER2 and HSPF2 replaced the older SEER, EER and HSPF in 2023. The test is tougher, so the new numbers are lower than the old ones for the same machine. Do not compare a SEER2 figure on a new quote with a SEER figure on an old one.

Ratings apply to a matched combination of outdoor unit, indoor coil and furnace or air handler. A quote should list the model numbers of all three and, ideally, the AHRI reference number for that match, so you can confirm the rating applies to what is being installed.

Refrigerants

Newly manufactured residential air conditioners and heat pumps now use R-454B or R-32. Both belong to a class called A2L, which means lower toxicity and mild flammability, and both have a much lower global-warming impact than R-410A, the refrigerant they replace. R-410A is being phased down. Existing R-410A systems can still be serviced and repaired.

What this means in practice:

  • A new outdoor unit cannot simply be connected to an old indoor coil designed for a different refrigerant. Expect both to be replaced together.
  • A2L systems have their own installation rules, including limits on refrigerant charge for the room size and, in some cases, leak sensors.
  • Anyone who opens a refrigerant circuit needs EPA Section 608 certification.

Ductless mini splits

A mini split avoids the attic duct problem entirely, because the refrigerant goes to the room instead of the air. That makes it a strong option for a garage conversion, an accessory dwelling unit, a bonus room over the garage, or a west-facing room that overheats every afternoon. Nearly all mini splits are inverter heat pumps, so they heat as well as cool.

Conventional mini splits need a technician to flare the line connections, pull a vacuum and release or add refrigerant. A separate category of DIY systems ships with pre-charged, quick-connect line sets so a homeowner can make the refrigerant connections without gauges or a vacuum pump. Zone Air is one example: its systems are AHRI Certified, use R-454B, and come with pre-charged line sets cut to the length each room needs, from 5 to 75 feet. The electrical circuit for any mini split still has to meet code, and a permit may apply.

Filtration and air quality add-ons

The add-on with the clearest benefit in this valley is a deep media filter cabinet, which lets the system use a high-MERV filter without starving the blower. See filtration for smoke and dust. Be more sceptical of electronic air cleaners and in-duct devices sold on health claims; ask what the device has been tested to remove and whether it produces ozone.