Light-commercial HVAC basics
Most shops, offices and restaurants in the valley are cooled by packaged rooftop units. Here is how they work, what upkeep they need in this climate, and what to ask a contractor.
Short answer
A rooftop unit is a complete heating and cooling system in one cabinet. In a hot, dusty climate it needs filters, coils, belts and the economizer checked on a schedule, usually quarterly. Before signing a lease or a maintenance contract, find out who is responsible for the equipment, how old it is, and exactly which tasks each visit includes.
What a rooftop unit is
A packaged rooftop unit, often shortened to RTU, holds the compressor, both coils, the blower and the heating section in a single weatherproof box on the roof. Supply and return ducts drop straight through the roof into the space below. One unit usually serves one zone with one thermostat, so a larger building has several.
The main parts and what they do:
| Part | Job | What goes wrong here |
|---|---|---|
| Condenser coil | Rejects heat to the outdoor air. | Dust and windblown debris mat the fins, raising pressures and power use. |
| Evaporator coil and filters | Cool and clean the supply air. | Filters load quickly in dusty, windy weather. A clogged filter can ice the coil. |
| Blower and belt | Move air through the ducts. | Belts crack and slip in roof heat. Many newer units use direct-drive motors instead. |
| Economizer | Brings in outdoor air for free cooling when it is cool and dry enough. | Dampers stick, actuators fail and sensors drift. A stuck-open damper pulls in 100°F air all afternoon. |
| Heating section | Gas burners or a heat pump cycle. | Igniters, flame sensors and, on heat pumps, reversing valves and defrost controls. |
| Condensate drain | Carries water off the cooling coil. | Traps dry out or clog and water ends up on the ceiling below. |
Why the economizer matters in this valley
The same day-to-night swing that helps a house helps a commercial building more. Offices and shops produce heat from people, lighting and equipment even when it is 62°F outside at 7 am. An economizer that works can cool the space with outdoor air through the morning and again after sunset, with the compressor off.
Economizers are also the part most often found broken, because a failed one does not stop the unit from cooling. It just costs more to run, quietly. Any maintenance visit should include moving the dampers through their range and confirming the controls respond. During wildfire smoke, outdoor air intake should be reduced to the minimum the building needs.
What a maintenance contract should include
Contracts vary widely. Read the task list, not the name of the plan. A useful agreement for a light-commercial rooftop unit states:
- Visit frequency. Quarterly is common. Restaurants and dusty sites may need filter changes more often.
- Filters. Size, rating and who supplies them. Filters replaced, not just inspected.
- Coil cleaning. Condenser coils washed at least once a year, before summer.
- Belts and bearings. Inspected, adjusted and replaced as needed, with belts included or priced.
- Economizer test. Dampers, actuator and sensors checked for real movement.
- Electrical checks. Contactors, capacitors and connections inspected, motor amps recorded.
- Refrigerant circuit. Operating pressures and temperatures recorded. Topping up without finding a leak is not maintenance.
- Condensate. Drain and trap cleared.
- A written report for each unit after each visit, with readings.
- What is excluded, and how repairs outside the contract are quoted and approved.
Questions to ask before you sign a lease
In many commercial leases the tenant pays for HVAC maintenance and sometimes replacement. Before committing to a space, find out:
- Who is responsible for maintenance, repair and replacement of each unit?
- How old are the units, and what refrigerant do they use? Units built for R-22 or R-410A can still be serviced, but refrigerant for them is being phased down and gets harder to source over time.
- Are there service records for the past few years?
- Does the cooling capacity suit your use? A restaurant or gym needs far more than the office that was there before.
- Is there a curb adapter or structural limit that affects what a replacement can be?
Repair or replace
There is no fixed age at which a rooftop unit must go. Replacement becomes the better choice when a major component such as a compressor or heat exchanger fails on an old unit, when repairs are recurring, or when the unit uses a refrigerant that is no longer made for new equipment. New rooftop units use lower global-warming refrigerants such as R-454B or R-32 and are rated in SEER2, EER2 or IEER depending on size.
Replacement on a commercial roof usually involves a crane, a permit, and in California an energy-code compliance check. Ask each bidder whether those are in the price. Anyone doing the work needs a state contractor's license in the right classification. The steps in how to choose a heating and air contractor apply to commercial jobs as well, and how HVAC financing works covers the terms to check if the purchase is financed.