What are common heating repair issues?
Heating systems in the valley sit idle for eight months and are then expected to start on the first cold night. Most failures come from a short list of parts.
Short answer
On gas furnaces, the most common problems are a dirty flame sensor, a failed igniter, a clogged filter tripping the high-limit switch, pressure switch or inducer faults, and worn blower parts. On heat pumps, look to defrost controls, reversing valves, capacitors and low refrigerant charge. A gas smell, a sounding carbon monoxide alarm or soot around the furnace are not repair issues to schedule. They are reasons to shut the system off and act immediately.
Check these before calling anyone
- Thermostat. Set to heat, set above room temperature, with working batteries.
- Filter. A clogged filter overheats a furnace and shuts the burners down. Replace it and try again.
- Power. The furnace has a switch nearby that looks like a light switch, and a breaker in the panel. Both should be on.
- Furnace door. A safety switch stops the unit if the blower door is not fully seated.
- Registers. Open and unblocked. Closing many registers raises the temperature inside the furnace.
- Gas supply. If other gas appliances also do not work, the problem is not the furnace.
Gas furnace problems
A modern furnace starts in a fixed order: the inducer fan runs, a pressure switch proves the vent is clear, the igniter glows or sparks, the gas valve opens, the flame sensor confirms flame, and the blower starts. When one step fails, the control board stops the sequence and usually flashes a fault code through a small window on the cabinet. The code chart is printed inside the door.
| Symptom | Likely cause | Notes |
|---|---|---|
| Burners light, then shut off within seconds | Dirty flame sensor | The most common furnace fault. The sensor rod gets coated and cannot detect flame. Cleaning it is a quick job for a technician. |
| Inducer runs, no ignition | Failed hot-surface igniter | Igniters are brittle and wear out. Replacement is routine. |
| Nothing after the inducer starts | Pressure switch not closing | Blocked vent, cracked hose, a failing inducer motor, or on condensing furnaces a blocked drain. |
| Heat runs briefly, stops, repeats | High-limit switch tripping | The furnace is overheating from low airflow: dirty filter, closed registers, dirty coil or a weak blower. |
| Burners run but no air from registers | Blower motor or capacitor | Shut the system off. Running burners without airflow overheats the heat exchanger. |
| Burnt-dust smell on first use | Dust on the heat exchanger | Normal for the first hour of the season. Should clear and not return. |
| Rumble, bang or roll-out at ignition | Dirty burners or delayed ignition | Needs service. Do not keep cycling it. |
| Pilot will not stay lit (older furnaces) | Worn thermocouple | Applies only to standing-pilot furnaces, which are now decades old. |
Cracked heat exchangers
The heat exchanger keeps combustion gases separate from the air blown into the house. A crack can allow those gases to mix with house air, so a confirmed crack means the furnace should not be used. It is also a diagnosis that leads straight to a replacement sale, which is why it is sometimes made too readily. If you are told the heat exchanger is cracked, ask to see the crack itself, in person or on camera, and ask for the combustion readings. A second opinion is reasonable.
Heat pump problems
- Outdoor unit covered in frost that does not clear. A light frost that melts off every so often is the defrost cycle working. Solid ice points to a failed defrost control or sensor, a fan problem or low refrigerant.
- Blows cool air in heating mode. During defrost this is normal for a few minutes. If it is constant, the reversing valve may be stuck or the system may be low on charge.
- Outdoor unit hums but does not start. Often a failed capacitor or contactor, the same parts that fail on air conditioners in summer.
- Runs constantly on a cold night. Heat pumps deliver gentler heat over longer cycles than furnaces. Long run times near freezing are expected. A house that cannot reach the setpoint is not.
Refrigerant does not get used up. A system that is low has a leak, and the repair is finding it, not topping up each year.
When it is a safety issue
Smell of gas: leave the house, do not operate switches, and contact the gas utility's emergency line or 911 from outside.
Carbon monoxide alarm sounding: get everyone outside into fresh air and call 911. Do not go back in to investigate.
Soot, scorch marks or a yellow, lifting flame: switch the furnace off and have it inspected before using it again.
California requires carbon monoxide alarms in homes with fuel-burning appliances or an attached garage. Test them when you change the filter in autumn.
Preventing the first-cold-night failure
Run the heat for fifteen minutes on a mild day in October. If something is going to fail, it is better to find out before the first near-freezing night, when schedules are full. A yearly heating check should include a combustion and carbon monoxide test, a look at the burners and heat exchanger, the flame sensor cleaned, and the safety switches tested. The maintenance calendar shows where that fits in the year. If you need to hire someone, see how to choose a contractor.